Page #153 background image
Safety
Information
Product
Information
Mechanical
Installation
Electrical
Installation
Getting
Started
Basic
parameters
Running
the motor
Optimization
SMARTCARD
operation
PC tools
Advanced
parameters
Technical
Data
Diagnostics
UL Listing
Information
Affinity User Guide 153
Issue Number: 5 www.controltechniques.com
Figure 11-3 Menu 3 Open-loop logic diagram
11.3 Menu 3: Speed feedback and speed control
2.01
Post ramp
reference
+
_
3.05
10.03
At zero speed
indicator
Zero speed
threshold
+
_
1.07
10.04
At or below min.
speed indicator
Minimum
speed
+
_
Overspeed trip
(O.SPd)
1.06
Max.
frequency
+
_
3.06
10.05
Below at-speed
window indicator
At speed
lower limit
+
_
3.07
10.07
Above at-speed
window indicator
At speed
upper limit
+
_
10.06
At speed
indicator
+20%
5.01
Motor
frequency
+
+
Slip
compensation
Menu 5
0.XX
0.XX
Key
Read-write (RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
X
X
X
X
Menu 2
0
1
1.10
Bipolar reference
select
NOR
The parameters are all shown at their default settings
1.03
Pre ramp
reference
3.09
Absolute at-speed
detect mode
0
1
+0.5Hz