EasyManuals Logo

Emerson Affinity User Manual

Emerson Affinity
274 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #206 background imageLoading...
Page #206 background image
Safety
Information
Product
Information
Mechanical
Installation
Electrical
Installation
Getting
Started
Basic
parameters
Running
the motor
Optimization
SMARTCARD
operation
PC tools
Advanced
parameters
Technical
Data
Diagnostics
UL Listing
Information
206 Affinity User Guide
www.controltechniques.com Issue Number: 5
Figure 11-36 SM-I/O 24V Protected digital I/O logic diagram
Figure 11-37 SM-I/O 24V Protected relay logic diagram
??.??
Any
unprotected
parameter
??.??
X.25
x(-1)
X.15X.05
T7 digital input 5
T7 digital
input 5 state
T7 digital
input 5 invert
T7 digital input 5
destination
??.??
Any
unprotected
parameter
??.??
X.26
x(-1)
X.16X.06
T8 digital input 6
T8 digital
input 6 state
T8 digital
input 6 invert
T8 digital input 6
destination
??.??
Any
unprotected
parameter
??.??
X.27
x(-1)
X.17X.07
T9 digital input 7
T9 digital
input 7 state
T9 digital
input 7 invert
T9 digital input 7
destination
Relay 1
0.XX
0.XX
Key
Read-write (RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
The parameters are all shown at their default setting
Any bit or
integer
parameter
Relay 2
Any bit or
integer
parameter