www.controltechniques.com Issue Number: 5
11.14.3 Fieldbus module category
Fieldbus module parameters
For information regarding Fieldbus module parameters, refer to the appropriate Solutions Module User Guide.
11.15 Menu 17: Building Automation Network
11.16 Menu 18: Application menu 1
11.17 Menu 19: Application menu 2
11.18 Menu 20: Application menu 3
All menu 20 parameters are transferred to the SMARTCARD when a 4yyy transfer is performed. See section 9.2.1 Writing to the SMARTCARD on
page 130 for more information.
Parameter
Range(
Ú) Default(Ö)
Type
17.01 ID code 0 to 599 402 RO Uni PT US
17.02 Software version 0.00 to 99.99
RO Uni NC PT
17.03 MAC/Node address 0 to 65535 1 RW Uni US
17.04 Baud rate 0 to 127
0
RW Uni US
17.05 Building Automation Network protocol 0 to 65535 RW Uni US
17.06 Received message counter 0 to 9999
RO Uni NC PT
17.07
MS/TP maximum master MAC
address
0 to 3000 127 RW Uni US
17.10 Device object identifier -19 to -32767 0 RW Bi US
17.12
Communications lost detection
timeout
-32,768 to +32,768 0
RW US
17.13 Communications loss action RW US
17.35 CRC errors
0 to 2
31
-1
RO Uni NC PT
17.38 Data format 0 to 255 0 RW Uni US
17.39 Response turn-around time 0 to 255 ms 5 RW Uni NC
17.44
Real-time clock (RTC) back-up battery
low
0 to 255
0ROUniNCPT
17.45 Communications OK flag
RO Bit
17.50
Building Automation Network error
status
RO Uni NC PT
17.51 Module software sub-version 0 to 99
RO Uni NC PT
Parameter
Range(
Ú) Default(Ö)
Type
18.01
Application menu 1 power-down
saved integer
-32,768 to +32,767
0
RW Bi NC PS
18.02 to
18.10
Application menu 1 read-only integer RO Bi NC
18.11 to
18.30
Application menu 1 read-write integer RW Bi US
18.31 to
18.50
Application menu 1 read-write bit OFF (0) or On (1) RW Bit US
Parameter
Range(
Ú) Default(Ö)
Type
19.01
Application menu 2 power-down
saved integer
-32,768 to +32,767
0
RW Bi NC PS
19.02 to
19.10
Application menu 2 read-only integer RO Bi NC
19.11 to
19.30
Application menu 2 read-write integer RW Bi US
19.31 to
19.50
Application menu 2 read-write bit OFF (0) or On (1) RW Bit US
Parameter
Range(
Ú) Default(Ö)
Type
20.01 to
20.20
Application menu 3 read-write integer -32,768 to +32,767
0
RW Bi NC
20.21 to
20.40
Application menu 3 read-write long
integer
-2
31
to 2
31
-1
RW Bi NC
RW Read / Write RO Read only Uni Unipolar Bi Bi-polar Bit Bit parameter Txt Text string
FI Filtered DE Destination NC Not copied RA Rating dependent PT Protected US User save PS Power down save