Safety
Information
Product
Information
Mechanical
Installation
Electrical
Installation
Getting
Started
Basic
parameters
Running
the motor
Optimization
SMARTCARD
operation
PC tools
Advanced
parameters
Technical
Data
Diagnostics
UL Listing
Information
Affinity User Guide 55
Issue Number: 5 www.controltechniques.com
Figure 3-53 Size 1 external EMC filter
All filter mounting holes are suitable for M6 fasteners.
Figure 3-54 Size 2 external EMC filter
All filter mounting holes are suitable for M6 fasteners.
DY
Z
V: Ground stud: M5
X: M6 threaded holes for footprint mounting of the drive
Y: Footprint mounting holes 6.5mm (0.256in)
Z: Bookcase mounting holes 6.5mm (0.256in)
L3L1 L2
H
B
A
CW
X
X
Y
Y
Z
Z
V
Cable size:
2.5mm
14AWG
2
CT part no.ManufacturerABCDHW
4200-6118
Schaffner
390 mm
(15.354 in)
423 mm
(16.654 in)
74 mm
(2.913 in)
45 mm
(1.772 in)
440 mm
(17.323 in)
100 mm
(3.937 in)
4200-6119
4200-6121
Epcos
450 mm
(17.717 in)
4200-6120
V: Ground stud: M5
X: M6 threaded holes for footprint mounting of the drive
Y: Footprint mounting holes 6.5mm (0.256in)
Z: Bookcase mounting slots 6.5mm (0.256in) wide
Y
ED
Z
L2
L1
L3
L
1
'
L
2
'
L
3
'
V
X
X
Y
Y
A
B
H
CW
Z
Z
Cable size:
4mm
10AWG
2
CT part no. Manufacturer A B C D E H W
4200-6210 Schaffner
371.5 mm
(14.626 in)
404.5 mm
(15.925 in)
125 mm
(4.921 in)
55 mm
(2.165 in)
30 mm
(1.181 in)
428.5 mm
(16.870 in)
155 mm
(6.102 in)
4200-6211 Epcos
431.5 mm
(16.988 in)

Table of Contents