Description of parameters (ToF Tool) Cerabar S/Deltabar S
104 Endress+Hauser
P01-xMx7xxxx-19-xx-xx-xx-032
Fig. 24: BASIC SETUP function group for the "Level" measuring mode and "Linear" level type
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
dry
wet
MassVolumeHeight
%
TANK VOLUME
TANK HEIGHT
MASS UNIT
CUSTOMER UNIT M
CUST. UNIT FACT. M
DAMPING VALUE
EMPTY CALIB. DENSITY UNIT
ADJUST DENSITY
HEIGHT UNIT
100% POINT
ZERO POSITION
CUSTOMER UNIT H
CUST. UNIT FACT. H
FULL PRESSURE
EMPTY PRESSURE
FULL CALIB.
ADJUSTED DENSITY
CALIBRATION MODE
HEIGHT UNIT
CUSTOMER UNIT H
CUST. UNIT FACT. H
VOLUME UNIT
CUSTOMER UNIT V
CUST. UNIT FACT. V
LIN. MEASURAND
Linear
Pressure
Linearized
Height
Linearized
Parameters marked with an asterisk "*"
are not always displayed. The display
depends on the settings of other parameters,
see the following Table.
Flow
Pressure
Level
PRESS. ENG. UNIT
CUSTOMER UNIT P
CUST. UNIT FACT. P
LEVEL MODE
MEASURING MODE
OPERATING MENU
MEASURED VALUE
QUICK SETUP
BASIC SETUP
DISPLAYSETTINGS
POSITION ADJUSTMENT
EXTENDED SETUP