Cerabar S/Deltabar S Description of parameters (FF configuration program)
Endress+Hauser 35
SENSOR_SN/
SENSOR SER. No.
Display
Index: 22
Data type: Visible String
Access: Read only
Displays the serial number of the sensor (11 alphanumeric characters).
SENSOR_CAL_METHOD
Selection
Index: 23
Data type: Unsigned8
Access: OOS
For displaying and selecting the last sensor calibration method used.
SENSOR_CAL_LOC
Entry
Index: 24
Data type: Visible String
Access: OOS
Enter the location where the sensor was calibrated (32 alphanumeric characters).
SENSOR_CAL_DATE
Entry
Index: 25
Data type: Date
Access: OOS
Enter the date and time the sensor was calibrated.
SENSOR_CAL_WHO
Entry
Index: 26
Data type: Visible String
Access: OOS
Enter the name of the person who calibrated the sensor (32 alphanumeric characters).
SENSOR_ISOLATOR_
MTL
Display
Index: 27
Data type: Unsigned16
Access: Read only
Displays the membrane material.
SENSOR_FILL_FLUID
Display
Index: 28
Data type: Unsigned16
Access: Read only
Displays the filling fluid.
SECONDARY_VALUE
Display
Index: 29
Data type: DS-65
Access: Read only
The SECONDARY_VALUE parameter is a structured parameter consisting of two elements.
VALUE
Displays the second process value, here the sensor temperature.
STATUS
Displays the status of the second process value.
!
Note!
You can transfer the value and status of the SECONDARY_VALUE parameter via the
CHANNEL parameter ( Page 67) in the Analog Input Block. For this purpose, the
CHANNEL must be set to "2".
SECONDARY_VALUE_
UNIT
Selection
Index: 30
Data type: Unsigned16
Access: Auto, OOS
Select the unit for the second process value.
See also parameter description for SECONDARY_VALUE.
Pressure Transducer Block
Parameter Description