Incoming acceptance and product identification Proline Promass E 300 PROFINET
18 Endress+Hauser
4.2.2 Sensor nameplate
Order code:
Ser. no.:
Ext. ord. cd.:
1
6
7
8
2
3
5
4
A0029206
3 Example of a sensor nameplate, part 1
1 Name of the sensor
2 Manufacturing location
3 Nominal diameter of the sensor; flange nominal diameter/nominal pressure; sensor test pressure; medium
temperature range; material of measuring tube and manifold
4 Sensor-specific information
5 CE mark, C-Tick
6 Order code
7 Serial number (ser. no.)
8 Extended order code (Ext. ord. cd.)
A0029207
4 Example of a sensor nameplate, part 2
1 Approval information for explosion protection, Pressure Equipment Directive and degree of protection
2 Permitted ambient temperature (T
a
)
3 Document number of safety-related supplementary documentation
4 2-D matrix code
5 Flow direction
6 Manufacturing date: year-month
Order code
The measuring device is reordered using the order code.
Extended order code
• The device type (product root) and basic specifications (mandatory features) are
always listed.
• Of the optional specifications (optional features), only the safety and approval-
related specifications are listed (e.g. LA). If other optional specifications are also
ordered, these are indicated collectively using the # placeholder symbol (e.g. #LA#).
• If the ordered optional specifications do not include any safety and approval-related
specifications, they are indicated by the + placeholder symbol (e.g. XXXXXX-ABCDE
+).