System integration Proline Promass E 300 PROFINET
86 Endress+Hauser
9.3.5 Startup configuration
If startup configuration is enabled, the configuration of the most important device
parameters is taken from the automation system and used. The following configuration is
taken from the automation system.
Startup configuration
(NSU)
Management:
Software revision
Write protection
Web server functionality
WLAN functionality
System units:
Mass flow
Mass
Volume flow
Volume
Corrected volume flow
Corrected volume
Density
Reference density
Temperature
Pressure
Concentration application package:
Coefficients A0 to A4
Coefficients B1 to B3
Medium type
Sensor adjustment
Process parameter:
Damping (flow, density, temperature)
Flow override
Low flow cut off:
Assign process variable
Switch-on/switch-off point
Pressure shock suppression
Empty pipe detection:
Assign process variable
Limit values
Response time
Max. damping
Corrected volume flow calculation:
External reference density
Fixed reference density
Reference temperature
Linear expansion coefficient
Square expansion coefficient
Measuring mode:
Medium
Gas type
Reference sound velocity
Temperature coefficient sound velocity
External compensation:
Pressure compensation
Pressure value
External pressure
Alarm delay
Diagnostic settings
Diagnostic behavior for diverse diagnostic information
Petroleum application package:
Petroleum mode
Water density unit
Water reference density unit
Oil density unit
Oil sample density
Oil sample temperature
Oil sample pressure
Water sample density
Water sample temperature
API commodity group
API table selection
Thermal expansion coefficient