Installation Proline Promass E 300 PROFINET
24 Endress+Hauser
Inlet and outlet runs
No special precautions need to be taken for fittings that create turbulence, such as valves,
elbows or T-pieces, as long as no cavitation occurs→  24.
A0029322 A0029323
Installation dimensions
For the dimensions and installation lengths of the device, see the "Technical
Information" document, "Mechanical construction" section .
6.1.2 Environmental and process requirements
Ambient temperature range
Measuring device –40 to +60 °C (–40 to +140 °F)
Order code for "Test, certificate", option JP:
–50 to +60 °C (–58 to +140 °F)
Readability of the local
display
–20 to +60 °C (–4 to +140 °F)
The readability of the display may be impaired at temperatures outside the
temperature range.
Dependency of ambient temperature on medium temperature→  243
If operating outdoors:
Avoid direct sunlight, particularly in warm climatic regions.
You can order a weather protection cover from Endress+Hauser. →  225.
System pressure
It is important that cavitation does not occur, or that gases entrained in the liquids do not
outgas.
Cavitation is caused if the pressure drops below the vapor pressure:
In liquids that have a low boiling point (e.g. hydrocarbons, solvents, liquefied gases)
In suction lines
Ensure the system pressure is sufficiently high to prevent cavitation and outgassing.
For this reason, the following mounting locations are recommended:
At the lowest point in a vertical pipe
Downstream from pumps (no danger of vacuum)
A0028777