Proline Prowirl 73 Description of device functions
Endress+Hauser 165
MOLE % i-C4H10 Description
Use this function to enter the i-butane (iso-butane) mole-% in the expected natural gas
mixture (total quantity of i-C4H10 and n-C4H10 max. 1.5 %).
User input
5-digit floating-point number
Factory setting
0 %
MOLE % n-C4H10 Description
Use this function to enter the n-butane mole-% in the expected natural gas mixture
(total quantity of i-C4H10 and n-C4H10 max. 1.5 %).
User input
5-digit floating-point number
Factory setting
0 %
MOLE % i-C5H12 Description
Use this function to enter the i-pentane (iso-pentane) mole-% in the expected natural gas
mixture (total quantity of i-C5H12 and n-C5H12 max. 0.5 %).
User input
5-digit floating-point number
Factory setting
0 %
MOLE % n-C5H12 Description
Use this function to enter the n-pentane mole-% in the expected natural gas mixture
(total quantity of i-C5H12 and n-C5H12 max. 0.5 %).
User input
5-digit floating-point number
Factory setting
0 %
MOLE % n-C6H14 Description
Use this function to enter the n-hexane mole-% in the expected natural gas mixture
(max. 0.1 %).
User input
5-digit floating-point number
Factory setting
0 %
MOLE % n-C7H16 Description
Use this function to enter the n-heptane mole-% in the expected natural gas mixture
(max. 0.05 %).
User input
5-digit floating-point number
Factory setting
0 %
MOLE % n-C8H18 Description
Use this function to enter the n-octane mole-% in the expected natural gas mixture
(total quantity of
n-octane, n-nonane and n-decane max. 0.05 %).
User input
5-digit floating-point number
Factory setting
0 %
Function description, NG AGA8-DC92/ISO 12213-2 group