Enertech Global 
EAV - EME/EMD Rev. A Models
Installaon and Operaons Manual







When installing a heang and cooling unit, there are several
items the installer should consider before placing the
equipment.

See illustraons in this manual for recommended unit
clearances.
The installer must verify that all applicable wiring, piping,
and accessories are correct and on the job site. All wiring,
line and low voltage, should comply with the manufacturer’s
recommendaons, the Naonal Electrical Code, and all local
codes and ordinances.
All Indoor EME/EMD Modules should be located in an indoor
area were the ambient temperature will remain between 55
o
F
and 95
o
F.
Unit should be located in a way that piping or other
permanently installed xtures do not have to be removed for
servicing.

This manual describes installaon and service procedures for
implementaon by Enertech trained specialists.
This is an original manual. It may not be translated without
the approval of Enertech. We reserve the right to make design
modicaons without prior noce.

The balance temperature is the outdoor temperature when
the heat pump’s stated output is equal to the building’s input
requirement. This means that the heat pump covers the whole
building’s output requirement down to this temperature.

EAV is equipped with two compressor heaters that heat the
compressor before start-up and when the compressor is cold.

In heang, the minimum outdoor air temperature at which
the unit will operate is -13 deg. F. In cooling, the minimum
temperature is 32 deg. F.

Disposal of the packaging should be completed by the installer.
Removal of all packaging and waste should be done in an
environmentally friendly way. Please recycle responsibly.
Do not dispose of used products with normal household waste.
It must be disposed of at a special waste staon or dealer who
provides this type of service. Please recycle responsibly.

The equipment contains R410A, a uorinated greenhouse gas
with a GWP value (Global Warming Potenal) of 2088. Do not
release R410A into the atmosphere.

The serial number can be found at the boom le on the rear
cover (see page 6).
Installer Manual
This installer manual must be le with the customer.











