The outdoor unit must be placed on a solid level base that can
support it’s weight. In many cases, a snow stand will be required
to keep the lower edge of the evaporator above the level of the
average local snow depth. It is recommended that the unit or
snow stand would rest on a concrete foundaon slab. If concrete
blocks are used they must rest on suitable base as not to sink or
sele over me.
The unit should not be posioned next to noise sensive walls,
for example, next to a bedroom.
Care must be exercised in unit placement so that recirculaon
of the outdoor air does not occur. This causes lower output and
impaired eciency.
The back of the unit must be sheltered from direct wind, which
negavely aects the defrost funcon. The air coil side of the
unit should face the wall of the home. Some condensaon may
drip from the drainage hole located at the base of the unit.
Make sure that water can properly drain way from the unit, and
home.
Do not place the unit directly on the lawn or other non-solid
surface. See illustraon below.
If there is a risk of snow or ice falling from a roof, a protecve
roof or cover must be erected to protect the heat pump, pipes
and wiring. See illustraon below.



