Enertech Global 22
EAV - EME/EMD Rev. A Models
Installaon and Operaons Manual
Move from the street to the unit’s nal locaon. If the ground
allows, use a pallet truck to move the unit to the set up locaon.
If that is not available and you must li the unit into place
please do so as described below.
The center of gravity is oset to one side (the right side
when looking at the front of the unit).
If the unit needs to be transported across so ground, such as
a lawn, a crane be used that can li the unit to the installaon
locaon. When the unit is lied with a crane, the packaging
must be undisturbed. (See the illustraon)
If a crane vehicle cannot be used the unit may be transported
on an extended hand truck with oversized turf res (dolly, two
wheeler). The unit must be taken from its heaviest side (right
side of unit when looking at the front). This unit is approaching
400 lbs so li accordingly using plenty of help as needed.
Recommended installaon for proper draining of
condensaon.
Before liing remove the packaging and the securing strap from
the pallet. Place liing straps around each machine foot. Liing
from the pallet to the base requires four persons, one for each
liing strap.
The condensate drain pan collects and drains away most of the
condensate from the heat pump.
It is important to the heat pump funcon that the condensate
run-o is not posioned so that it can cause damage to the
house. Run-o should be checked regularly especially during
the autumn for obstrucons by leaves and branches. Clean
if necessary. The condensate (up to 13 gallons/24 hrs) that
collects in the trough should be routed away by a pipe to an
appropriate area, it is recommended that the shortest outdoor
stretch possible is used.