Section 3 — Config Parameters
ENSONIQ DP/4+ Reference Manual 9
Feedback D to C
Amount =00
06 — (Config Dependent)
This parameter, similar to parameter 05, is dependent on how Units C and D are routed together
(determined by parameter 03).
(b)ypass (k)ill
A=b B=b C=b D=b
07 — Bypass Kill (Unit) A 09 — Bypass Kill (Unit) C
08 — Bypass Kill (Unit) B 10 — Bypass Kill (Unit) D
These parameters determine what happens when you bypass a unit (red LED lit). When set to
bypass (b), the red LED is solidly lit, and only the dry signal passes through the unit. When set to
kill (k), the red LED is flashing, and no signal passes through the unit.
When the units are set to bypass (b), it’s like setting the Mix to 00. When the units are set to kill
(k), it’s like setting the Volume to 00, although your preset values are not affected.
In order to use a foot switch to bypass a unit, it must be set to function as a DP/4+ controller (see
the description of System•MIDI parameters 45 to 48 in Section 4 — System•MIDI).
Notes
When using Kill in a configuration involving unit feedback pairs (for example, AB Unit
Routing=feedback):
• Killing Unit B in a feedback pair mutes the signal.
• Killing Unit A does NOT mute the signal. Unit B can still pass dry signal.