Page #45 background image
Connecting AC and PoE Power
SecureStack C3 Installation Guide 3-17
PoE Redundant Power System
IfyouareconnectinganoptionalPoEredundantpowersupply(C2RPSPOE),refertothe
installationinstructionssuppliedwiththeSecureStackC2RPSPOE.Theswitchis
connectedtoaC2RPSPOEusingaC2RPSPOEcable.
Ifyouareinstallingtheswitchasastandalonedevice,proceedtoConnectingtoConsole
PortforLocalManagementonpage 318.Ifyouareinstal lingswitchesinastack
configuration,proceedtoStackManagerSelectiononpage 317.
Stack Manager Selection
Whenyouinstallandconnectallthehighspeedstackingcablestotheswitchesinthe
stackbeforeapplyingpowertotheswitches,thefollowingoccurs:
•Theswitchthatwillmanage(Manager)thestackisautomaticallyestablishedwithall
otherswitchesestablishedasMemberswitchesinthestack.Whentheswitches
completetheirinitializations,oneoftheswitchesinthestackwillilluminateits
ManagerLED,indicatingthatitisthestackManager.TheManagerLEDoneach
Memberswitchwillbeoff.
•ThehierarchyoftheswitchesthatwillfunctionasbackupManagerisalsodetermined
incasethecurrentManager
malfunctions,ispowereddown,orisdisconnectedfrom
thestack.
•TheConsoleportoneachMemberswitchisdeactivated.OnlytheConsoleportonthe
ManagerswitchisactiveforoutofbandconfigurationtosettheIPaddress,
password,andotherconfigurationsettings.
OnceyouknowwhichswitchistheManager,
proceedtoConnectingtoConsolePortfor
LocalManagementonpage 318.
Caution: The C2RPS-POE power supply does not support non-PoE compliant
SecureStack switches. Do not try to connect the power cable from this C2RPS-POE
power supply to any SecureStack switch that does not have a “P” suffix in the model name
(for example, C3G124-24). Otherwise, damage to the device may result.
Precaución: La fuente de poder C2RPS-POE no es compatible con switches
SecureStack que no cumplan con el estándar PoE. No intente conectar el cable de
corriente de esta fuente de poder C2RPS-POE a ningún switch SecureStack que no
tenga el sufijo “P” en el nombre del modelo (por ejemplo, C3G124-24). De lo contrario, el
dispositivo puede dañarse.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C3G124-24P and is the answer not in the manual?

Enterasys SecureStack C3G124-24P Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C3G124-24P
CategoryNetwork Router
LanguageEnglish

Related product manuals