Using the Reset Switch
4-8 Troubleshooting
Using the Reset Switch
Ifyouforgettheswitchloginpassword,usetheResetswitchtoresettheloginpassword
tothedefaultpassword,asdescribedinthe followingprocedure.
Figure 4-3 Reset Switch
Port(s) goes into
standby for no
apparent reason.
Loop condition detected. Verify that Spanning Tree is enabled. Refer to the
SecureStack C3 Configuration Guide for the instructions to
set the type of STA.
Review the network design and delete unnecessary loops.
If the problem continues, contact Enterasys Networks for
technical support.
User parameters
(IP address, device
and module name,
etc.) were lost
when the switch
power was cycled.
Clear NVRAM was set using
CLI commands.
Reenter the lost parameters as necessary. Refer to the
SecureStack C3 Configuration Guide for the instructions to
configure the switch using CLI commands.
If the problem continues, contact Enterasys Networks for
technical support.
Table 4-2 Troubleshooting Checklist (continued)
Problem Possible Cause Recommended Action
1 Reset switch
STACK UP
STACK DOWN
À