EasyManua.ls Logo

Epson Aculaser C9200N - Page 173

Epson Aculaser C9200N
441 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON AcuLaser C9200N Revision D
DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 173
Confidential
5. Snap off the C-clip [4], one collar [5] and remove the Feed Roller [6].
A D J U S T M E N T
R E Q U I R E D
When installing the Feed Roller with a new one, make sure to reset the life counter.
(Refer to Chapter 5 “ADJUSTMENT”) (p313))
[4]
[5]
[6]
Separation Roller (Standard Cassette)
C H E C K
P O I N T
The pickup roller should be replaced, whenever the separation roller is replaced.
1. Slide out the standard paper cassette.
2. Remove two Screws [1] and the Separation Roller ounting bracket assy [2].
E1
4038F2C002DB
[1]
[2]