VT6L Maintenance 4. Alarm
18 VT series Maintenance Manual Rev.2
4.2.3 Alarm Notifying Method
The Manipulator status becomes warning and displays warning message if any parts
required to perform replacement or grease up.
For details, refer to the following manual.
Status Code / Error Code List
The alarm notifying method can be configured by the output bit of the Remote I/O.
The Remote I/O can be configured in the EPSON RC+ 7.0- [Setup] - [System
Configuration] - [Controller] - [Remote Control].
For details, refer to the following manual.
EPSON RC+ 7.0 Users Guide 12.1 Remote I/O.
The Controller enters the warning state if an alarm occurs.
Alarm1 to Alarm9 set in the output bit of the remote I/O monitor the occurrence of warnings
every 5 minutes.
The alarm occurrence and output timing on the controller are different. It may be output to
the remote I/O up to 5 minutes after the alarm is occurred on the controller.
4.2.4 How to Cancel the Alarm
An alarm occurs when the consumption rate of the parts reaches 100%.
The alarm cannot be canceled by executing the Reset command or restarting the Controller.
The alarm can be canceled by the following method.
Operation from [Maintenance] dialog box of the EPSON RC+ 7.0
HealthCtrlReset Command
HealthRBReset Command
Refer to the following section to change the alarm information in the same steps.
4.2.2 How to Edit the Maintenance Information
NOTE
NOTE

Table of Contents

Other manuals for Epson VT6-A901S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson VT6-A901S and is the answer not in the manual?

Epson VT6-A901S Specifications

General IconGeneral
BrandEpson
ModelVT6-A901S
CategoryRobotics
LanguageEnglish

Related product manuals