Managing Hardware with CLI Commands
Determining Operating Status 5-17
Table 5-21 lists the port types for the port-type argument.
Values for CLI Output Fields
The tables in this section list the output fields and the data that they can display for the show commands for
various hardware components. These commands are described in detail in the Ports, Circuits, and Tunnels
Operations Guide for the SmartEdge OS. These tables appear in the following sections:
Output Fields for the show chassis Command
Output Fields for the show disk Command
Output Fields for the show hardware Command
Output Fields for the show port Command
Output Fields for the show chassis Command
Table 5-22 describes the output fields for the show chassis command (in any mode).
Table 5-21 Port Types
Port Type Description
atm ATM OC-3 or ATM OC-12 port
ethernet Ethernet or Gigabit port (any version)
oc192 POS port (OC-192c/STM-64c)
Table 5-22 Output Fields for the show chassis Command
Field Description
Current platform is Type of chassis:
SE1200—Standard SmartEdge 1200s chassis.
SE1200 NEBS—NEBS-compliant SmartEdge 1200n chassis.
Slot n—Slot number for this unit.
Configured type Slot is configured for the following card:
traffic-card-type—Traffic card is configured; see Table 5-23 for a list of traffic card types.
1
xcrp—Controller card of any type is configured.
none—Slot is not preconfigured.
Installed type Slot has a card installed:
traffic-card-type—Traffic card is installed; see Table 5-23 for a list of traffic card types.
xcrp—Controller card of any type is installed; use the show hardware command (in any mode) to display the
type.
none—Slot is empty.
unknown—Controller card is inserted but not initialized.
Initialized State of the card:
No—Packet Processing ASICs (PPAs) have not been initialized for this card.
Yes—PPAs have been initialized for this card.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ericsson Redback Networks SmartEdge 1200 and is the answer not in the manual?

Ericsson Redback Networks SmartEdge 1200 Specifications

General IconGeneral
BrandEricsson
ModelRedback Networks SmartEdge 1200
CategoryNetwork Router
LanguageEnglish

Related product manuals