Controller Card Alarms
Alarms and Probable Causes B-3
Controller Card Alarms
Table B-4 lists the supported alarms that apply to controller cards.
Circuit pack failure Critical ReplaceableUnitProblem Yes
Circuit pack mismatch Critical ReplaceableUnitTypeMismatch Yes
Circuit pack missing Critical ReplaceableUnitMissing Yes
Circuit pack overheating Major LineCardProblem Yes
Circuit pack power-on diagnostic failed Major ReplaceableUnitProblem Yes
Circuit pack reset completed Warning OperationNotification Yes
Diagnostic fail Major ReplaceableUnitProblem Yes
Loss of backplane clock Major ReplaceableUnitProblem Yes
Software download completed Warning OperationNotification Yes
Software download failed Warning OperationFailure Yes
Synchronization failure Critical TimingProblem Yes
Voltage failure detected Major ReplaceableUnitProblem Yes
Table B-4 Controller Card Alarms
Description Severity Probable Cause Service Affecting
Backup fail: peer dead
1
Major ReplaceableUnitProblem Yes
Controller auto switch completed
1
Major OperationNotification Yes
Controller code mismatch Major ReplaceableUnitTypeMismatch Yes
Controller exerciser switch failed
1
Major OperationFailure Yes
Controller fail Critical ReplaceableUnitProblem Yes
Controller forced switch requested
1
Major OperationNotification Yes
Controller manual switch requested
1
Major OperationNotification Yes
Controller missing
1
Critical ReplaceableUnitMissing Yes
Controller overheating Major ReplaceableUnitProblem Yes
Controller power-on diagnostic failed Major ReplaceableUnitProblem Yes
Controller switch completed
1
Major OperationNotification Yes
Controller switch failed
1
Major OperationFailure Yes
Controller temperature critical Major ReplaceableUnitProblem Yes
Controller temperature hot Minor ReplaceableUnitProblem Yes
Controller type mismatch Major ReplaceableUnitTypeMismatch Yes
Table B-3 Controller and Traffic Card Alarms (continued)
Description Severity Probable Cause Service Affecting

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ericsson Redback Networks SmartEdge 1200 and is the answer not in the manual?

Ericsson Redback Networks SmartEdge 1200 Specifications

General IconGeneral
BrandEricsson
ModelRedback Networks SmartEdge 1200
CategoryNetwork Router
LanguageEnglish

Related product manuals