Loading...
10 TOOLS
0460 896 274
- 64 -
© ESAB AB 2013
The following information can be read in the error log menu:
The error number of the error
The date on which the error has occurred
The time at which the error has occurred
The unit in which the error has occurred
The error's error management code
Units
1 = cooling unit 4 = remote control unit
2 = power source 5 = AC-unit
3 = wire feed unit 8 = control panel
10.1.1 Error code descriptions
Fault code Description
1 Program memory error, (EPROM)
There is a fault in the program memory.
This fault does not disable any functions.
Action: Restart the machine. If the fault persists, send for a service
technician.
2 Microprocessor RAM error
The microprocessor is unable to read/write from/to a certain memory position
in its internal memory.
This fault does not disable any functions.
Action: Restart the machine. If the fault persists, send for a service
technician.
3 External RAM error
The microprocessor is unable to read/write from/to a certain memory position
in its external memory.
This fault does not disable any functions.
Action: Restart the machine. If the fault persists, send for a service
technician.

Table of Contents