When deciding where to install the switch, ensure that:
The switch is accessible and cables can be connected easily.
Water or moisture cannot enter the case of the unit.
Air-flow around the unit and through the vents in the side of the case is not
restricted. You should provide a minimum of 25mm (1-inch) clearance.
No objects are placed on top of the unit.
Units are not stacked more than four high if the switch is free-standing.
M
EDIA
T
YPES
AND
D
ISTANCES
The connectors, media types, and maximum distances are described in Table 2-1.
*E
XTREME
N
ETWORKS
PROPRIETARY
. C
AN
BE
CONNECTED
TO
1000BASE-LX
ON
SINGLE
-
MODE
FIBER
USING
A
MAXIMUM
DISTANCE
OF
5,000 M
ETERS
.
Table 2-1:
Media Types and Distances
Standard Media Type
Mhz/Km
Rating
Maximum
Distance
1000BASE-SX 50/125um Multimode Fiber
50/125um Multimode Fiber
62.5/125um Multimode Fiber
62.5/125um Multimode Fiber
400
500
160
200
500 Meters
550 Meters
220 Meters
275 Meters
1000BASE-LX 50/125um Multimode Fiber
50/125um Multimode Fiber
62.5/125um Multimode Fiber
10u Single-mode Fiber
400
500
500
550 Meters
550 Meters
550 Meters
5,000 Meters
1000BASE-LX10* 10u Single-mode Fiber 10,000 Meters
100BASE-FX 50/125um Multimode Fiber
(half-duplex operation
50/125um Multimode Fiber
(full-duplex operation)
62.5/125um Multimode Fiber
(half-duplex operation)
52.5/125um Multimode Fiber
(full-duplex operation)
400 Meters
2000 Meters
400 Meters
2000 Meters
100BASE-TX
10BASE-T
Category 5 UTP Cable (100Mbps)
Category 3 UTP Cable (10Mbps)
100 Meters
100 Meters