Installation: Labeling, Cabling, Mounting, cont’d
MLC 226 Series • Installation: Labeling, Cabling, Mounting2-12
PRELIMINARY
Side Panel Features: Reset Button and LED
Reset button and LED — Pressing this recessed
button causes various IP functions and Ethernet
connection settings to be reset to the factory
defaults. See “Resetting the unit” for details.
Resetting the unit
There are four reset modes (numbered 1, 3, 4, and 5
for the sake of comparison with an Extron IPL
product) that are available by pressing the Reset
button on the side panel. The Reset button is
recessed, so use a pointed stylus, ballpoint pen, or
Extron Tweeker to access it. See the following table
for a summary of the modes.
CAUTION
Review the reset modes carefully.
Using the wrong reset mode may result in unintended loss of flash
memory programming, port reassignment, or controller reboot.
The reset modes listed below close all open IP and Telnet connections and close
all sockets. Also, the following modes are separate functions, not a
continuation from Mode 1 to Mode 5.
Reset Mode Comparison/Summary
Mode
Activation Result Purpose/Notes
1 Hold down the
recessed Reset button
while applying power
to the MLC.
3 Hold down the Reset
button for about 3 sec.
until the Reset LED
blinks once, then press
Reset momentarily
(<1 sec.) within 1 sec.
4 Hold down the Reset
button for about 6 sec.
until the Reset LED
has blinked twice
(on
ce at 3 sec., again
at 6 sec.). Then press
Reset momentarily
(for <1 sec.) within 1
second.
5 Hold down the Reset
button for about 9 sec.
until the Reset LED
has blinked three
times (once at 3 sec.,
again at 6 sec., again
at 9 sec.). Then press
Reset momentarily
(for <1 sec.) within 1
second.
The MLC reverts to the factory default
firmware.
Event scripting will not start if the
MLC is powered on in this mode. All user
files and settings (drivers, adjustments, IP
settings, etc.) are maintained.
Mode 3 turns events on or off. During
resetting, the Reset LED flashes 2 times if
events are starting, 3 times if events are
stopping.
Mode 4
Enables ARP capability.
Sets the IP address back to factory default.
Sets the subnet back to factory default.
Sets the default gateway address back to
the factory default.
Sets port mapping back to factory default.
• Turns DHCP off.
• Turns events off.
Reset LE
D flashes 4 times in quick succession
during reset.
Mode 5 performs a complete reset to factory
defaults (except the firmware).
• Does everything mode 4 does.
• Resets almost everything that can be set via
the Real Time Adjustments part of the
configuration program: all audio settings,
limit initial power up volume, power
up/down delay, auto power down
, and
misc. options. This does not affect an
optional MLS switcher, however.
• Clears driver-port associations and port
configurations (IR/RS-232).
• Removes button configurations.
• Resets all IP options.
• Removes scheduling settings.
Removes/clears all files from switcher.
The Reset LED flashes 4 times in quick
success
ion during the reset.
Use mode 1 to
remove a version of
firmware if
incompatibility
issues arise.
Events must be
turned on if you
want to change IP
settings or
scheduling.
Mode 4 enables you
to set IP address
information using
ARP and the MAC
address.
Mode 5 is u
seful if
you want to start
over with
configuration and
uploading, and also
to replace events.
MLC 226
Right Side
Reset
button
Reset
LED

Table of Contents

Related product manuals