Installation
Current consumption of IO-Link power supply [Logic]
An input current at pin 1 (L+) of 100 ... 150 mA is required for operation.
1
2
3
Fig. 7: Wiring diagram: IO-Link operation
1
PELV fixed power supply for the load
voltage supply
2
Integrated drive EMCS-ST
3
IO-Link master with IO-Link interface