EasyManua.ls Logo

Festo EMCS-ST - System Parameters

Festo EMCS-ST
114 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Festo — EMCS-ST — 2021-03b
IO-Link
101
ProcessDataOutput Bit
15 ... 5 4
1)
3 2 1 0
Status data Move
"Inter-
mediate"
Quit Error Move
"Out"
Move
"In"
Index.Subindex 0x0029.5
(41.5)
0x0029.3
(41.3)
0x0029.2
(41.2)
0x0029.1
(41.1)
1) From firmware version v19.0.4.107_release
Tab. 49: ProcessDataOutput telegram structure
15.2.4
System parameters
The "System Commands" system parameters contain all command data (e.g. start and stop, power
stage control, ...) displayed as buttons in the application software interface to control the drive
system.