Festo — EMCS-ST — 2021-03b
Automatic data backup (backup/restore active) can result in very high data traffic with the IO-Link
master and should only be activated if required.
The table shows all parameters that are transferred when data storage is executed.
Index.
Subindex
Name Description Data type
(Length)
Identification parameters
0x0018.0
(24.0)
Application
Specific Tag
Text field for application information, max. 32 charac-
ters
String
(£32 bytes)
0x0019.0
(25.0)
Function Tag Text field for function information, max 32 characters String
(£32 bytes)
0x001A.0
(26.0)
Location Tag Text field for location information, max. 32 characters String
(£32 bytes)
Device data
0x0100.0
(256.0)
Speed "In" 10-stage speed specification from the maximum value
for the "Mov
In
" motion to the reference end position
"Ref"/end position "Lim
In
"
– 1 = 10% (default)
...
10 = 100%
è Instruction manual for the drive system, technical
data
UInteger8
(1 bytes)
0x0101.0
(257.0)
Speed "Out" 10-stage speed specification from the maximum value
for the "Mov
Out
" motion to the end position "Lim
Out
"
– 1 = 10% (default)
...
10 = 100%
è Instruction manual for the drive system, technical
data
UInteger8
(1 bytes)
0x0102.0
(258.0)
Force
1)
10-step force/torque specification for the force-con-
trolled "Mov
Out
" motion from the "Pos
Start Press
" posi-
tion to the "Lim
Out
" end position
– 1 = 10% (default)
...
10 = 100%
è Instruction manual for the drive system, technical
data
UInteger8
(1 bytes)