3. Installation
3-25
Festo P.BE-SPC11-SYS-ASI-EN en 0203NH
3.3.4 Connecting the operating voltage and the A S-Interface bus
Recommendation: In order to connect the load voltage cable
and the AS-Interface bus cable use the following accessories
from Festo:
Accessories
Type designation
AS-Interface combi power pack ASI-CNT-115/230VAC
AS-Interface bus cable (yellow) KASI-1.5-Y-100
Additional supply cable (black) KASI-1.5-Z-100
AS-Interface cable cap ASI-KK-FK
AS-Interface cable socket ASI-SD-F K or ASI-SD-F K180
Addressing device ASI-PRG-ADR
Identification labels ISB6x10
Installation instructions
Caution
In order to avoid interference caused by electromagnetic
influences:
S Connect the earth connection on the left-hand side of the
housing with low impedance (short cable with large
cross-sectional area) to the earth potential.
S Connect a protective conductor with sufficient cross
sectional area to the drive, if this is not mounted on an
earthed machine stand.