Seite/Page 32 - Kaptitel/Chapter 2: 22.10.19
2.4.3 Opening the GFK sound insulation capsule
Fig. 2.4-1: Lash closuresGFK sound insulation capsule with lash closures
Fig. 2.4-2: Lash closuresTo open the lash closures pull the handle in arrow
direction and lift the lash of the closure pin. After lifting
of the lashes, the sound isolation cover upper pars can
be removed.
2.5 Special maintenance notes and arrangements at long periods of stand
still time or shutdown
Stand still is divided into the following groups:
Short-term standstill (1 to 3 months).
Medium-term standstill / winter storage (3 to 6 months).
Long-term standstill (storage) / shutdown (more than 6 months).
WarningAt irregular using intervals make shure that the generator
runs till the engine is hot every 2 weeks. Without this water
can gather in the engine oil and in the exhaust line and cause
generator damage.