The Panda Generator
22.10.19 Kapitel/Chapter 3: The Panda Generator - Seite/Page 55
3.3.4 Sensors and switches for operation surveillance
Fig. 3.3.4-1: TThermo-switch at cylinder headThermo-switch at cylinder head
The thermo-switch at the cylinder head serves to monitor the
generator temperature.
Fig. 3.3.4-2: Thermo-switch at exhaust elbowThermo-switch at water-cooled exhaust elbow
This thermo switch is located at the water-cooled exhaust
elbow union and serves to monitor the temperature of the
fresh water cooling system. It takes a measurement at the
hottest spot, since the combustion gases are guided from the
cylinder head for the exhaust elbow.
Fig. 3.3.4-3: Thermo-switch coilThermo-switch in the generator coil
1. Generator coil
2. Thermo-switch
3. Housing
Two thermo switches are located inside the winding to
protect the generator coil, which for safety reasonsare
installed independently in parallel.
Sample picture
1
3
2