FLIR DM286 USER MANUAL Document Identifier: DM286-en-US_AA
43
9.17.2 FLEX Clamp Adaptor Current and Frequency Measurements
FLIR Flex Clamp Adaptors (Models TA72 and TA74, for example) and other clamp adaptors
connect to the DM286 to display current measurements made by a clamp adaptor.
1. Turn the function dial to the
position.
2. Connect a Clamp adaptor as shown in Fig. 9.13.
3. Set the Range of the Flex Clamp Adaptor to match the range of the DM286.
4. Use the RANGE button to select the range of the DM286 (1, 10, 100 mv/A). The
selected range appears on the top of the DM286 display.
5. Operate the Flex Clamp per instructions provided with the Flex Clamp meter.
6. Read the current measured by the Flex Clamp on the DM286 LCD. The frequency also
appears on the DM286 secondary display.
Fig. 9.13 FLEX Clamp Adaptor Application