724/725/726
Calibration Manual
ii
Upper Display mA Measurement Tests......................................................... 28
Lower Display mA Measurement Tests (725 and 726)................................. 29
Lower Display Frequency Measurement Test (725 and 726) ....................... 30
Lower Display Frequency Source Test (725 and 726) .................................. 31
Lower Display 4-Wire Resistance Measurement Tests................................. 32
Lower Display 3-Wire RTD Measurement ................................................... 33
Lower Display Thermocouple Measurement Tests....................................... 34
Lower Display Thermocouple Source Test ................................................... 35
Lower Display mA Source Tests (725 and 726) ........................................... 36
Lower Display mV Source Tests................................................................... 37
Lower Display Voltage Source Tests ............................................................ 37
Lower Display Ohms Source Tests ............................................................... 38
Pressure Module Input (725/726).................................................................. 39
Calibration Adjustment...................................................................................... 39
Setup.............................................................................................................. 39
Initiating Communication (724 and 725) ...................................................... 40
Calibration Adjustment Procedures (724 and 725) ....................................... 41
Cal Volts Input .......................................................................................... 41
Cal Volts Output ....................................................................................... 42
Cal mA Input (Fluke 725 Only) ................................................................ 43
Cal mA Output (725 Only) ....................................................................... 44
Cal mV Input............................................................................................. 45
Cal mV Output .......................................................................................... 46
Cal Thermocouples ................................................................................... 47
Cal Ohms Hi Source.................................................................................. 48
Cal Ohms Low Source .............................................................................. 49
Cal RTD Low Range................................................................................. 50
Cal RTD Hi Range .................................................................................... 51
Cal ISO Volts ............................................................................................ 52
Cal ISO mA............................................................................................... 53
Calibration Adjustment Procedures (726) ..................................................... 54
Initiating Communication ......................................................................... 54
Calibrating Isolated mA Input................................................................... 55
Calibrating Isolated Voltage Input ............................................................ 56
Calibrating mA Input ................................................................................ 57
Calibrating mA Output.............................................................................. 58
Calibrating Voltage Input.......................................................................... 59
Calibrating Voltage Output ....................................................................... 60
Calibrating Low Ohms Source.................................................................. 61
Calibrating High Ohms Source ................................................................. 62
Calibrating Ohms Measure........................................................................ 63
Calibrating Thermocouple mV Output ..................................................... 64
Calibrating Thermocouple mV Input ........................................................ 65
Calibrating Thermocouple CJC:................................................................ 66
Replaceable Parts............................................................................................... 67

Table of Contents

Other manuals for Fluke 724

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 724 and is the answer not in the manual?

Fluke 724 Specifications

General IconGeneral
Temperature Range-10°C to 55°C
Thermocouple TypesJ, K, T, E, R, S, B, L, U, N
Current Measurement0 to 24 mA
Operating Temperature-10°C to 55°C
FunctionProcess calibrator
RTD TypesPt100, Pt500, Pt1000
Voltage Measurement0 to 10 V
Loop Power24 V DC
DisplayDual Display
Power Supply4 AA batteries
Resolution0.1 °C
Storage Temperature-20 °C to 60 °C
Battery Life25 hours
Relative Humidity0 % to 90 %
Safety ComplianceCSA C22.2 No. 1010.1:1992