Appendix A: Log Messages for Connections that Fail
107
802.1X: Server certificate unverified
Ignore this message if you did not select the option Check Server
Certificate in the profile in AirCheck Manager.
802.1X: Server certificate is bad
The option Check Server Certificate was selected in the profile in AirCheck
Manager, but an incorrect certificate was loaded into the tester.
DHCP: Timeout occurred
(without the message DHCP: Success after this
one)
The access point could not communicate with the external DHCP server.
The access point has an internal DHCP server, but it is disabled.
The DHCP server is at its limit for the number of users.
The tester and the access point are both configured for WEP security,
but they have different key settings.
DHCP: No offer received
When this follows the message DHCP: Timeout occurred, see the causes
above.
Static IP: ARP received. Address already in use
The option Manual (Static) was selected in the profile in AirCheck
Manager, but a duplicate IP address was found on the network.
Message Possible Reasons for the Connection Failure