The theoretical maximum throughput on a Gigabit Ethernet link is 125 MB/s. To calculate the
bandwidth required for specific stream configuration on D400e camera use the following formula:
=
ℎ
= 2
1
= 1
2
= 1
= 2
ℎ
= ℎ
∗ ℎ
∗ ℎ
∗ ℎ
+
1
∗ 1
∗ 1
∗ 1
+
2
∗ 2
∗ 2
∗ 2
+
∗
∗
∗
Example of a bandwidth calculation is given below (Depth profile 640x480@30fps with both left and
right infrared streams enabled, RGB profile 848x480@30fps):
ℎ
= 1
= 2
= 640
ℎ
= 1
= 2
= 480
= 848
= 480
ℎ
= 1
= 2
=
= 30
ℎ
= 2 ∗ 640 ∗ 480 ∗ 30 +
1 ∗ 640 ∗ 480 ∗ 30 +
1 ∗ 640 ∗ 480 ∗ 30 +
2 ∗ 848 ∗ 480 ∗ 30 =
61286400 / = 61.29 /