EasyManua.ls Logo

Fronius Calibration system 2.0 - Technical Specifications

Fronius Calibration system 2.0
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
Calibration sys-
tem 2.0
Mains voltage 100 - 240 V AC
Mains voltage tolerance +15 / -10 %
Mains frequency 50/60 Hz
Mains fuse protection (slow-blow) 4 A
Primary current 3 A @ 100 V AC
1.5 A @ 240 V AC
cos phi power factor 0.99
Internal power supply 24 V DC +/- 1%
Output current 10 A (-25 °C - +55 °C)
Max. permissible loading of the sock-
ets
8 A
Degree of protection IP 20
Type of cooling AF
Max. permissible current of the load 600 A
Max. permissible loading of the load 24 kW for 20 s
Max. permissible voltage of the load 113 V peak
EMC device class EN 61010 -1:2010
Safety symbols CE
Dimensions l x w x h 686 x 304 x 497 mm
Total dimensions (with trolley) 1103 x 738 x 1017 mm
Weight 31.5 kg
Total weight (with trolley) 120 kg
Ambient temperature 0 – 40 °C
Load resistance 8 x 480 mOhm parallel
Wire speed
measuring sys-
tem
Operating voltage 5 - 30 V DC
Open-circuit current 55 mA
Wire speed 0 - max. 30 m/min
Degree of protection IP 20
EMC device class EN 61010 -1:2010
Safety symbols CE
Weight 1.5 kg
Ambient temperature 0 – 40 °C
Fuse protection T2A