Technical data
Calibration sys-
tem 2.0
Mains voltage 100 - 240 V AC
Mains voltage tolerance +15 / -10 %
Mains frequency 50/60 Hz
Mains fuse protection (slow-blow) 4 A
Primary current 3 A @ 100 V AC
1.5 A @ 240 V AC
cos phi power factor 0.99
Internal power supply 24 V DC +/- 1%
Output current 10 A (-25 °C - +55 °C)
Max. permissible loading of the sock-
ets
8 A
Degree of protection IP 20
Type of cooling AF
Max. permissible current of the load 600 A
Max. permissible loading of the load 24 kW for 20 s
Max. permissible voltage of the load 113 V peak
EMC device class EN 61010 -1:2010
Safety symbols CE
Dimensions l x w x h 686 x 304 x 497 mm
Total dimensions (with trolley) 1103 x 738 x 1017 mm
Weight 31.5 kg
Total weight (with trolley) 120 kg
Ambient temperature 0 – 40 °C
Load resistance 8 x 480 mOhm parallel
Wire speed
measuring sys-
tem
Operating voltage 5 - 30 V DC
Open-circuit current 55 mA
Wire speed 0 - max. 30 m/min
Degree of protection IP 20
EMC device class EN 61010 -1:2010
Safety symbols CE
Weight 1.5 kg
Ambient temperature 0 – 40 °C
Fuse protection T2A
97