Control panel
Gas test / wire threading control panel
No. Function
(1) Operating status LED
Shows steady green when the de-
vice is ready for use
(2) Gas-test button
For setting the required gas flow
rate on the pressure regulator
Gas will flow out for 30 seconds af-
ter the gas-test button is pressed.
Press the button again to stop the
gas flow prematurely.
No. Function
(3) Wire retract button
For retracting the wire electrode with no accompanying flow of gas or current
The wire electrode can be retracted using one of two methods:
Method 1
Retracting the wire electrode using the preset wire retract speed:
Press and hold "Wire retract" button
- The wire electrode will be retracted 1 mm (0.039 in.) after the wire retract button
is pressed
- After a short pause, the wirefeeder continues to retract the wire electrode. If the
wire retract button remains pressed, the speed will increase every second at a
rate of 10 m/min (393.70 ipm) until the preset wire retract speed is reached
Method 2
Retracting the wire electrode in 1 mm increments (0.039 in. increments) – always
press the wire retract button for less than one second (tap)
NOTE!
Do not allow long lengths of wire electrode to be retracted, as the wire electrode is
not wound onto the wirespool or the welding wire drum when retracted.