Fitting the welding system to a conventional robot
Safety
WARNING!
Work that is carried out incorrectly can cause serious injury or damage.
The following activities may only be carried out by trained and qualified personnel.
The Operating Instructions for system components, particularly the chapter entitled
"Safety rules", must be observed.
WARNING!
An electric shock can be fatal.
Before starting the work described below:
Turn the power source mains switch to the "O" position
Disconnect the power source from the mains
Ensure that the power source remains disconnected from the mains until all work has
been completed.
WARNING!
Risk of serious injury and damage from articles being dropped.
For all of the screw connections referred to below:
Check after fitting to ensure they are tight
Check following an unusual operating situation (e.g. crash) to ensure they are tight
Check regularly to ensure they are tight
Fitting the TPS/i
welding system
to a conventional
robot
Individual components must be fitted to the robot in the following order:
1. Robot holder(s) must have already be fitted first
2. SplitBox
3. For CMT applications only: Wire buffer
4. CrashBox Drive /i
5. WF Robacta Drive
6. Torch hosepack
7. Interconnecting hosepack
8. Unreeling wirefeeder