EasyManua.ls Logo

Fuji Electric RYS...S3-VVS Series - Page 16

Fuji Electric RYS...S3-VVS Series
251 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MHT258a (Engl.)2-6
(c) Additional data for motor with providing speed reduction gear, gear head unit
(i) Motor with gear ratio 1/9
1) 0.03 to 0.75 [kW]
GYN GRN. GYN
Type □□□□□□SAG-G09
300 500 101 20 40 751
Actual speed reduction ratio 1/9
Rated 333.3Speed [r/min]
Max. 555.5
Rated torque [Nm] 1.23 2.54 4.9 9.8 18.1
Breakdown (max.) torque [Nm] 3.68 7.36 14.7 29.4 54.3
Direction of motor rotation (*2) CCW
Backlash (max.) [min] 40 30
Mass (weight) [kg] 0.7 2.1 3.8
(ii) Motor with gear ratio 1/25
1) 0.03 to 0.75 [kW]
GYN GRN. GYN
Type □□□□□□SAG-G25
300 500 101 20 40 751
Actual speed reduction ratio 1/25
Rated 120Speed [r/min]
Max. 200
Rated torque [Nm] 3.19 6.37 12.7 25.5 48
Breakdown (max.) torque [Nm] 9.56 19.1 38.2 76.4 144
Direction of motor rotation (*2) CCW
Backlash (max.) [min] 40 30
Mass (weight) [kg] 0.7 2.1 3.8
(*1) 15 micrometers for over the rated speed.
(*2) Direction of gear-output-shaft rotation is CCW (counter-clockwise), when motor shaft rotates forward(*).
The direction is viewed from a point facing the drive-end of motor.
(*3) Breakdown (max.) torque and maximum current values are selected in accordance with the following paired combination of amplifier
and motor types.
Lower value/higher value
When the same output [kW] rating of amplifier and motor/when amplifier size is one step larger than the motor frame No. size
corresponding with amplifier.
Refer to 2.3.
(*4) Rated torque are continuous operating torque , on condition that motors are mounted heat sink which size are bellow table.
Motor type Heat sink size [mm]
GYS500DC1-S8 200 × 200 × 6
GYS101DC1-S 200 × 200 × 6
GYS201DC1-S 250 × 250 × 6
GYS401DC1-S 250 × 250 × 6
GYS751DC1-S 300 × 300 × 6