148
< Modelmenu(Airplane/Glider/MulticopterFunctions) >
[Corresponding model type]: Glider, general
Acceleration
Setting method
ŏ Acceleration rate setting (Rate)
ŏ The return time after operation (Damping)
can be set.
ŏ The operation point at acceleration
and deceleration can be set. When an
operation point is exceeded, acceleration is
performed.
ŏ Select [Acceleration] at the model
menu and call the setup screen shown
below.
Acceleration setting can be performed at
(OHYDWRU(OHYDWRUĺ&DPEHUDQG$LOHURQĺ
Rudder. (Glider only)
ŏ This setting is divided into elevator setting and
camber setting. The setting method is the same.
ŏ Camber setting sets the acceleration function
for Elevator to camber mixing. Setting is not
performed when Ele to camber mixing is INH.
ŏ The acceleration function can be set for both the
up side and down side.
ŏ Function ON/OFF switch setting is performed for
Aileronń Rudder setting only.
ŏ Aileronń Rudder setting is acceleration
function setting for Aileronń Rudder mixing. It is
not performed when Aileronń Rudder mixing is
INH.
Note: When using the acceleration function,
since the servo stroke is large, make your
settings so there is no binding of your linkage.
Operationuptothis
rangewillinitiate
acceleration.
Actposition
Theratetheangle
increases.
Tonextpage
2/3:Ele(Elevator) → Camber
3/3:Ail(Aileron) → Rudder
Thereturntimeafteroperation(Damping)
canbeset.
(Firstreturn)1 〜 100(Slowreturn)
(Accelerationdoesn'tfunctionas0.)
Whenusingthis
function,Tap[INH].
(ONisdisplayed.)
Conditiongroup/
singlemodeselection
(Gr./Sngl)
Currentposition
ŏReturn to Model menu