GAT Access 6100 Terminal Series
Commissioning & Configuration
62
HB_GAT-ACCESS6100--EN_14
www.gantner.com
- Position on Card: Number of the user defined segment.
- Block Number: Number of the block that shall be read within the user defined segment.
- Mask: The data, which is read from the defined block on the data carrier, is combined with
logical AND with this Mask value to determine which value is relevant for comparison
with the Result value (see next field).
- Result: The result of the AND calculation of the read data and the Mask value are compared with
this Result value. If both values match, access is granted. If not, access is denied.
In the previous example, the Mask value of "00000000FFFFFF000000…" means that the first 4 bytes of the read
data are not relevant (Mask value is entered in hex, i.e., 8 digits = 4 bytes with all bits set to "0"). The next 3 bytes
are relevant ("FFFFFF" = 3 bytes with bits set to "1") with the remaining bytes again not relevant. This means
that all data carriers, which have the information "M36” in ASCII or "4D3336" in hex value at position 5 to 7 of the
read data, have access permission.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gantner GAT Access 6100 Series and is the answer not in the manual?

Gantner GAT Access 6100 Series Specifications

General IconGeneral
BrandGantner
ModelGAT Access 6100 Series
CategoryTouch terminals
LanguageEnglish

Related product manuals