GAT Access 6100 Terminal Series
Troubleshooting & FAQ
www.gantner.com
HB_GAT-ACCESS6100--EN_14
91
Locker 2:
- Read: false
- Position on Card: 5
- Clear number: false
Start Date:
- Mode: None
- Hours: 0
- Minutes: 0
End Date:
- Mode: None
- Hours: 0
- Minutes: 0
Fingerprint:
- Position on Card Base: 6
Timeouts:
- Access allowed screen: 3000
- Access denied screen: 3000
MIFARE:
- Site Key: 73E0…
- Subsite: 00
- Enable Subsite: false
8.19 How do I configure a GAT Access 6100 for offline emergency mode?
For the GAT Access 6100, there is the possibility to load an Offline License into the terminal. With this license, the
terminal checks if a specific code string is stored in a defined position on the data carrier and if the data carrier has
access permission.
The Offline License can be ordered from GANTNER Electronic GmbH. The serial number and MAC address of the
GAT Access 6100 is required and the license is valid only for one terminal.
To load the license into the GAT Access 6100, GAT Config Manager software from GANTNER Electronic GmbH is
used (see chapter "5.5. Configuration of Offline Emergency Mode for a GAT Access 6100 ").
8.20 What is the data carrier certificate?
The GAT Access 6100 checks the data carrier certificate to confirm that it is a GANTNER data carrier. In basic
configuration only GANTNER data carriers are allowed.
It is possible to order a device license that deactivates the certificate test thereby allowing third party data carriers to
be used.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gantner GAT Access 6100 Series and is the answer not in the manual?

Gantner GAT Access 6100 Series Specifications

General IconGeneral
BrandGantner
ModelGAT Access 6100 Series
CategoryTouch terminals
LanguageEnglish

Related product manuals