GAT Access 6100 Terminal Series
Operation
www.gantner.com
HB_GAT-ACCESS6100--EN_14
77
When in pause mode it is possible to stop/cancel the countdown process before the configured runtime has ended.
For this functionality, the correct timeout and action must be set in the configuration settings (see chapter "5.4.3 List
of Configuration Settings") via the "Remaining period mode" setting in the "Application -> General" section and the
"Remaining period break" settings in the "Application -> Timeouts" section).
If, during a pause, the equipment is not resumed during the defined "Remaining period break" the set "Remaining
period mode" will determine:
- If the countdown process is cancelled immediately
- If the countdown process is resumed and the terminal relay is switched on (= equipment on)
- If the countdown process is resumed and the terminal relay is switched off (= equipment off)
6.8 Online Mode and Emergency Mode
Online mode is the regular mode for operation. The GAT Access 6100 must communicate with a server/host that
decides if the data carrier is valid and if the controlled door or turnstile may be unlocked.
If the server/host is not available or is not responding to the requests of the GAT Access 6100 the terminal will switch
into the Emergency mode (if configured). In this mode, the access terminal only reads the site key of the data carrier
and grants access if this is valid (i.e., the same as the site key in the GAT Access 6100).
For the GAT Access 6100 F Enrollment Station, the configuration settings determine if the device displays the icons
that allow users to enroll and check fingerprints, or if these icons are not displayed.
Emergency mode is not indicated via the display or the status LEDs.
6.9 Out of Order Screen
When communication of the GAT Access 6100 is interrupted and the GAT Access 6100 is not configured for
Emergency mode, the terminal switches into Out of Order mode. The following message is displayed on the LC
display.
Figure 6.11 - Out of order screen of GAT Access 6100
The GAT Access 6100 will listen on the configured TCP/IP port (default 8000).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gantner GAT Access 6100 Series and is the answer not in the manual?

Gantner GAT Access 6100 Series Specifications

General IconGeneral
BrandGantner
ModelGAT Access 6100 Series
CategoryTouch terminals
LanguageEnglish

Related product manuals