GE Power Management PQM Power Quality Meter 7-17
7 MODBUS COMMUNICATIONS 7.3 MODBUS MEMORY MAP
7
USER
DEFINABLE
REGISTER
INDEX
continued
018B Register address for User Data 000B ***** 1 --- F1 0
018C Register address for User Data 000C ***** 1 --- F1 0
018D Register address for User Data 000D ***** 1 --- F1 0
to
↓↓
01F7 Register address for User Data 0077 ***** 1 --- F1 0
01F8 Reserved
to
01FF Reserved
Actual Values (Input Registers) Addresses - 0200-0E1F
STATUS 0200 Switch Input Status --- --- --- F101 N/A
0201 LED Status Flags --- --- --- F102 N/A
0202 LED Attribute Flags --- --- --- F103 N/A
0203 Output Relay Status Flags --- --- --- F104 N/A
0204 Alarm Active Status Flags 1 --- --- --- F105 N/A
0205 Alarm Pickup Status Flags 1 --- --- --- F105 N/A
0206 Alarm Active Status Flags 2 --- --- --- F106 N/A
0207 Alarm Pickup Status Flags 2 --- --- --- F106 N/A
0208 Alarm Active Status Flags 3 --- --- --- F107 N/A
0209 Alarm Pickup Status Flags 3 --- --- --- F107 N/A
020A Aux. 1 Active Status Flags 1 --- --- --- F105 N/A
020B Aux. 1 Pickup Status Flags 1 --- --- --- F105 N/A
020C Aux. 1 Active Status Flags 2 --- --- --- F106 N/A
020D Aux. 1 Pickup Status Flags 2 --- --- --- F106 N/A
020E Aux. 1 Active Status Flags 3 --- --- --- F107 N/A
020F Aux. 1 Pickup Status Flags 3 --- --- --- F107 N/A
0210 Aux. 2 Active Status Flags 1 --- --- --- F105 N/A
0211 Aux. 2 Pickup Status Flags 1 --- --- --- F105 N/A
0212 Aux. 2 Active Status Flags 2 --- --- --- F106 N/A
0213 Aux. 2 Pickup Status Flags 2 --- --- --- F106 N/A
0214 Aux. 2 Active Status Flags 3 --- --- --- F107 N/A
0215 Aux. 2 Pickup Status Flags 3 --- --- --- F107 N/A
0216 Aux. 3 Active Status Flags 1 --- --- --- F105 N/A
0217 Aux. 3 Pickup Status Flags 1 --- --- --- F105 N/A
0218 Aux. 3 Active Status Flags 2 --- --- --- F106 N/A
0219 Aux. 3 Pickup Status Flags 2 --- --- --- F106 N/A
021A Aux. 3 Active Status Flags 3 --- --- --- F107 N/A
021B Aux. 3 Pickup Status Flags 3 --- --- --- F107 N/A
021C General Status --- --- --- F109 N/A
021D Encrypted Passcode --- --- --- F1 N/A
021E Reserved
to
↓↓
022F Reserved
Table 7–10: PQM MEMORY MAP (Sheet 3 of 40)
GROUP ADDR
(HEX)
DESCRIPTION RANGE STEP
VALUE
UNITS and
SCALE
FORMAT FACTORY DEFAULT
Notes: * Data type depends on the Command Operation Code. ** Any valid Actual Values or Setpoints address.
*** Maximum Setpoint value represents “OFF”. **** Minimum Setpoint value represents “OFF”.
***** Maximum Setpoint value represents “UNLIMITED”.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Power Quality Meter Series and is the answer not in the manual?

GE Power Quality Meter Series Specifications

General IconGeneral
BrandGE
ModelPower Quality Meter Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals