ELECTRICAL SYSTEM
PROBLEM
POSSIBLE CAUSE REMEDY
II
I
Engine Temperature
Faulty Temperature Sender.
Replace Temperature Sender.
I
Gauge does not work.
Loose wiring/terminal connections. Verify wiring connections.
Faulty Temperature Gauge.
Replace Temperature Gauge.
Hour Meter does not
Loose wiring/terminal connections. Verify wiring connections.
work.
Faulty Alternator.
Contact your Gehl Dealer for assistance.
Faulty Hour Meter. Replace Hour Meter.
Starter will not engage Seat or Restraint Bar Switch is not
Make certain operator is in the Seat
when key is turned to
activated or
is
faulty. with the Restraint Bar down.
"Start".
Replace Switches
as
needed.
I
Poor connections to Starter Relay Verify Relay connections.
I
(Instrument Panel).
Battery Terminals or Cables are loose Clean Battery terminals and cables and
or corroded. retighten them.
Faulty Starter Relay (#I)(Instrument
Contact your Gehl Dealer for assistance.
Panel).
Battery will not Battery Terminals or Cables are loose
Clean Battery Terminals and Cables and
recharge.
or corroded.
retighten them. Replace Cables as
needed.
I
Battery or Alternator
is
defective.
Contact your Gehl Dealer for assistance.
Work Lights not
Single Light doesn't work: Light bulb
Check and replace light bulb
as
needed.
functioning properly.
burned out, faulty wiring.
Check wiring connection to Light.
No lights at all: 20 ampere (Lights)
Refer to wiring diagram, check circuit,
Fuse may be blown.
and locate trouble before replacing Fuse.
Faulty Light Switch or Poor Ground. Replace Light Switch. Check Ground
Wire connections.
,
Lift/Tilt Lock
Wiring to Solenoids is disconnected or Refer to wiring diagram, locate trouble,
Solenoids do not work.
faulty.
and repair as needed.
Faulty Seat or Restraint Bar Switch.
Contact your Gehl Dealer for assistance.
Faulty Solenoid Valve Coil.
Contact your Gehl Dealer for assistance.
Faulty Hydraulic Solenoid Relay (#2)
Contact your Gehl Dealer for assistance.
(Instrument Panel).
50