EasyManua.ls Logo

General Dynamics R2670 Series - 6-7.2 System Initiated Dispatch Trunk IEP II Signaling; Figure 6-7. Dispatch Test Screen - System Init Trunk I and Trunk I EP II Signaling

Default Icon
402 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 6-7. Dispatch Test Screen – System Init Trunk I and Trunk I EP II Signaling
6-7.2 System Initiated Dispatch Trunk I
EP II Signaling
The radio receives the control channel message to
move to a voice channel, and switches to that voice
channel. When the radio detects the low-speed data
word, the radio unmutes and stays on the voice
channel until the test is terminated.
To set up testing, activate the Trunk mode per
paragraph 6-5, place the cursor in the "Meter:" field
and press the softkey SYSTEM INIT to view
current data and test status for a system initiated
trunked test sequence. Within the Display zone,
place the cursor in the "Sig Type:" field and press
the softkey TRUNK I EP II to select Trunk I EP II
signaling. A screen similar to figure 6-7 appears.
Parameter selection is similar to Radio Initiated
Dispatch Trunk I described in paragraph 6-6.1.
101