Appendix E
MOTOROLA ANALOG TRUNKING OPTION
ERROR AND WARNING MESSAGES
E-1 ERRORS
If an error occurs during a test, the test ends. To
run the test again, correct the mistake and restart
the test. Errors fall into three categories: setup
errors, radio errors and trunking analyzer test set
errors. A summary of setup and radio error
messages follows.
E-1.1 Setup Error Messages
The following errors occur when data entered
by the user is incorrect. Note, these errors are
detected after the Start Test softkey is pressed,
and prevent the test from starting. The user must
enter the correct data and press the start button
again.
Invalid System ID Entered
CC Tx Frequency Out of Range
CC Rx Frequency Out of Range
VC Tx Frequency Out of Range
VC Rx Frequency Out of Range
CC Tx Channel Number Out of Range
CC Rx Channel Number Out of Range
VC TxChannel Number Out of Range
VC RxChannel Number Out of Range
CC Tx to VC Rx Offset Out of Range
CC Tx to CC Rx Offset Out of Range
Prefix Out of Range
Fleet ID Out of Range
Subfleet ID Out of Range
Unit ID Out of Range
E-1.2 Radio Error Messages
ISW Timeout
The trunking analyzer did not receive a
response from the radio in the time
allowed. This could indicate a radio
problem or an incorrect test type entered
by the user.
Connect Tone Timeout
The trunking analyzer did not receive the
connect tone in the time allowed. This
could indicate a radio problem or an
incorrect test type entered by the user.
Test Terminated by User
The user has halted the test prior to
completion by pressing the Stop Test
softkey, or by changing the mode of the
trunking analyzer (e.g., entering
calibration or standard mode).
Invalid ISW Call Type Received
The trunking analyzer did not receive the
ISW call type expected for the selected test
sequence. This could indicate a radio
problem or incorrect input from the user
such as test type, Fleet ID, etc.
High-Speed ACK Timeout
The trunking analyzer did not receive the
High-Speed Acknowledge tone in the time
allowed (Trunk I signaling only.) This
could indicate a radio problem or an
incorrect test type entered by the user.
E-1