ASTRO TRUNKING ERROR AND WARNING MESSAGES
G-1 ERRORS
If an error occurs during a test, the test ends. To
run the test again, correct the mistake and restart
the test. Errors fall into three categories: setup
errors, radio errors and trunking analyzer test set
errors. A summary of setup and radio error
messages follows.
G-1.1 Setup Error Messages
The following errors occur when data entered by
the user is incorrect. Note that these errors are
detected after the Start Test softkey is pressed,
and prevent the test from starting. The user must
enter the correct data and press the start button
again.
Invalid System ID Entered
CC Tx Frequency Out of Range
CC Rx Frequency Out of Range
VC Tx Frequency Out of Range
VC Rx Frequency Out of Range
CC Tx Channel Number Out of Range
CC Rx Channel Number Out of Range
VC TxChannel Number Out of Range
VC RxChannel Number Out of Range
CC Tx to VC Rx Offset Out of Range
CC Tx to CC Rx Offset Out of Range
Prefix Out of Range
Fleet ID Out of Range
Subfleet ID Out of Range
Unit ID Out of Range
G-1.2 Radio Error Messages
ISW Timeout
The trunking analyzer did not receive a
response from the radio in the time allowed.
This could indicate a radio problem or an
incorrect test type entered by the user.
Connect Tone Timeout
The trunking analyzer did not receive the
connect tone in the time allowed (Motorola
Analog Trunking only). This could indicate a
radio problem or an incorrect test type entered
by the user.
Test Terminated by User
The user has halted the test prior to completion
by pressing the Stop Test softkey, or by
changing the mode of the trunking analyzer
(e.g., entering calibration or standard mode).
Invalid ISW Call Type Received
The trunking analyzer did not receive the ISW
call type expected for the selected test
sequence. This could indicate a radio problem
or incorrect input from the user (e.g., test type
or Fleet ID).
High-Speed ACK Timeout
The trunking analyzer did not receive the high-
speed acknowledge tone in the time allowed
(Trunk I signaling only.) This could indicate a
radio problem or an incorrect test type entered
by the user.
G-1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the General Dynamics R2670 Series and is the answer not in the manual?

General Dynamics R2670 Series Specifications

General IconGeneral
BrandGeneral Dynamics
ModelR2670 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals