11
1.4 Power Requirements
The power required to operate the URC-200 (V2) is +28 VDC nominal applied to the DC Input
port J1, with the following characteristics:
Operating Voltage range - +22 to +34 VDC
Current 3.5 Amps Maximum
1.5 Environmental Operation and Storage
Environmental characteristics of the URC-200 (V2) are shown in Table 4.
Table 4 - Environmental Characteristics
Characteristics Specification
Temperature (Operating)
-20° C to +55° C
Altitude (Operating)
15,000 feet, MSL
Altitude (Storage)
50,000 feet, MSL
Humidity (Operating)
95% relative non-condensing
Temperature (Storage)
-50
°
C to +70
°
C
Humidity (Storage)
95% relative non-condensing