General Dynamics C4 Systems URC-200 (V2)
50
Table 11 - Remote Transceiver Operation Commands
CODE NAME DESCRIPTION
TRANSCEIVER
KEYPAD
Command sent to the transceiver to
disregard the current remote command (or
partial command) and re-sync. Transceiver
The "$" Command followed by three digits
in the following format adjusts the remote
squelch.
“$xxx”
where:
‘xxx’ = a decimal number from 000–255.
When in remote mode, the transceiver uses
the remote squelch value rather than the
squelch knob setting. The remote value is
initialized to the knob value when a remote
session is initiated.
keypad response for
the $ Command. The $
Command is
equivalent to the
SQUELCH Control on
the Transceiver’s front
panel, see Paragraph
4.4.1)
Initialization
Initializes all channels to the default values
(AM, PT, low power, 225 MHz, Wideband
(25 kHz), Aviation Mode Off).
6
MODE
and turn ON
transceiver
(See Paragraph 4.4.2)
The “L” Command followed by a 0, 1, 2,
or 3 selects the intensity of the
transceiver’s display backlighting
"L0" = Lamp Off
"L1" = Lamp Low
"L2" = Lamp Med
9
LAMP
(See Paragraph 4.4.3)
The “J” Command followed by a 0 or 1
selects whether the transceiver’s internal
speaker is OFF or ON.
"J0" = Speaker Off
"J1" = Speaker On
3
SPKR
(See Paragraph 4.4.4)
The "K" Command performs the self-
calibration of the transceiver’s preselector