76 GS15
plus
16. After the adjustment is correct, reinstall the X motor. To do so,
place the X motor on its standoff. Make sure the cable extends
upward toward the ceiling.
17. Loosely install the three screws removed in step 8. Each must have
a #8 lock washer and #8 flat washer. The lock washer must be
closest to the screw head.
18. While applying pressure, tighten the three screws.
19. Turn on power to the plotter.
20. Load vinyl in the plotter, install the knife holder and cut a test plot.
If closure problems persist, repeat the Adjustment Procedure from
step 1.
21. If no closure problem appears, select AXIS SWAP mode. Cut a test
plot. If closure problems persist, repeat the X Axis Backlash
Adjustment Procedure.
22. If no closure problem appears, reinstall the front cover.