EasyManuals Logo

GHL ProfiLux 4 Programming Guide

GHL ProfiLux 4
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #36 background imageLoading...
Page #36 background image
ProfiLux 4 Programming Guide
EN 2017-02-06 36
For a group with 3 pumps, the following switch-on pattern is obtained:
Step
Pump 1
Pump 2
Pump 3
1
on
off
off
2
off
on
off
3
off
off
on
4
on
off
off
5
off
on
off
6
on
off
on
7
on
off
off
etc.
Sequence 2 Similar to Sequence 1, but the pumps are not switched one after the other,
instead of that, they are activated in an alternating order.
For a group with 3 pumps, the following switch-on pattern is obtained:
Step
Pump 1
Pump 2
Pump 3
1
on
off
off
2
off
on
off
3
off
off
on
4
off
on
off
5
on
off
off
6
off
on
off
7
off
off
on
etc.
Surge 1 The pumps of this group are switched on one after the other until all pumps are
active, then the pumps are switched off again in the same order until all are off. The time
until the switching state changes again can be set (see beneath).
For a group with 3 pumps, the following switch-on pattern is obtained:
Step
Pump 1
Pump 2
Pump 3
1
on
off
off
2
on
on
off
3
on
on
on
4
off
on
on
5
off
off
on
6
off
off
off
7
on
off
off
etc.
Surge 2 Similar to Surge 1. This setting allows all pumps to be switches off in the reverse
order as they were previously switching on.

Table of Contents

Other manuals for GHL ProfiLux 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GHL ProfiLux 4 and is the answer not in the manual?

GHL ProfiLux 4 Specifications

General IconGeneral
ModelProfiLux 4
CategoryController
Power Supply12V DC
pH Ports2
Redox Ports1
Conductivity Ports1
Level Ports4
Digital Inputs4
12V Outputs4
Real-time clockYes, with battery backup
Digital Outputs4
ExpandableYes
ConnectivityUSB, Wi-Fi, LAN
DisplayGraphic LCD display
Expansion Slots4
Processor32-bit
Channels16
Operating Temperature0°C to 50°C